OPA-105.LCD

Stand-alone partial-flow Smoke Meter Module

 

With built-in LCD display, keypad and printer.

Suitable for testing smoke and opacity emission of Diesel engine-equipped vehicles of any kind.

Available as full version for heavy-duty emission tests or as light version for pre-check, diagnostic and repair.

Powered by ASSEMBLAD OPA-KING ready-for-working temperature-controlled smoke bench.

Suitable for use as test equipment by means of ASSEMBLAD test line software, and for building a stand-alone combi gas/smoke emission tester by adding an ASSEMBLAD Gas Analyzer module.

Approved for statutory tests. Recommended for intensive use.

 

MAIN FEATURES:

  • Available as light version or full version including smoke shut-off valve.
  • Capable to run any emission test procedure on Diesel engine-equipped vehicles of any kind.
  • User-selectable operating modes: free acceleration, continuous, loaded, etc.
  • ASSEMBLAD Service software available for remote monitoring.
  • Built-in backlit LCD screen, keypad and printer.
  • Automatic zeroing function (typical 15 sec.).
  • Fast warm-up time (typical 5 minutes) at power-on only.
  • Easy and quick maintenance, cleaning and calibration.
Category:
Technical Data
Measure Range   Ris.
Opacity 0 ÷ 9,99 (m-1)
0,01 (m-1)
Smoke
0 ÷ 9,99 %
0,1 %
Smoke temp.
0 ÷ 100 °C
0,1 °C
Bench temp.
0 ÷ 100 °C 0,1 °C
RPM (*) 0 ÷ 9999 rpm 1 rpm/1′
Oil Temp.(*)
0 ÷ 130 °C 0,1 °C
Power and size
Power supply 12V DC or 220V AC
Weight 2.3 Kg
Dimensions (LxHxP)
345x270x160mm

 

Depliant

Download the Depliant

Scrivici
Hai bisogno di assistenza?
Assistenza Assemblad
Ciao...
Come possiamo aiutarti?